General
Maintenance
Cleaning your tape machine regularly can minimize most problems.
A.
Clean Brushes/Tank
1.
Remove water bottle.
2.
Remove Moistening Tank - pull up over shelf lip
3.
Remove moistening brushes - must have minimum 2 brushes to work properly
4.
Wash Out tank & brushes in warm, soapy water
B.
Clean Lower Tape Plate
1.
Remove Upper Tape Plate - 700UTP (REF FM12EL)
2.
Spray Lower Tape Plate with foaming cleaner
3.
Dry and if glue residue remains spray with WD-40 (or similar
product) to remove dried glue
C.
Clean Shears see Service Figure 1 below
1.
Remove bottle & water tank
To
Clean Upper Shear -
2.
Pull Rocker Stop Rod on right side of machine with right hand and
keep in this position until next step
has been accomplished
3. Reach
inside machine where tank was removed, pull Upper Shear down
and swing out.
4.
Clean shear with foamy cleaner and WD-40 to remove all dirt & dry glue
Shear should not be scraped with hard objects as resulting scratches
will cause rapid build-up of glue
To
reinstall Upper Shear -
1.
Pull Rocker Stop Rod forward with right
hand and hold in this position.
2.
Tip knife up into cutting position and push upward so that the knife comes
up between lower shear and shear rollers -700THBR (Ref FM18)
NOTE:
You may have to slightly push lower shear back to get Upper Shear to fit between
this shear and guide rollers.
For
a Quick Cleaning -
Remove
bottle & tank. Raise the Upper Shear by pushing up on the Yoke Assembly. The
Upper Shear is attached to the Yoke Assembly by a shear rod. Push & hold up
the Yoke Assembly Shelf. Spray the Upper Shear with a foaming cleaner and/or
WD-40. Dry it off.
D.
Clean Feed Upper Feed Wheel
If
you notice a build up of tape in the grooves of the Upper Feed Wheel 500MUFX
(Ref PW77X)
a wire brush can be used to clean it our. Using a 1/4" drill, run the wire
brush in between the grooves of the Upper Feed Wheel.

Service
Figure 1
Drop
the Upper Shear By Moving Rod Forward, push down & pull forward on Upper
Shear
If
you can't find the answers here, then please feel free to call us at
1-800-899-9389
or

Tigerseal®
Products is not affiliated with MCM/Phoenix®
Tigerseal®
Products is not affiliated with Better Packages®
Inc.
|